6 Q: If there was an accumulation of gas in that hole, is the air course such that it would dispel the gasout of it?

A: No it is impossible to make an air course that would dispel it.

Q: Was the quantity of air adequate to ventilate the mines?

A: We had a great deal more air than the law calls for.

Q: When did you last measure it?

A: Mr. Morgan measures it every month

Q: Would the quantity of air vary?

A: No, I don’t think it did.

Q: Is the second south level a portion of the mine where an explosion has occuredwithin 12 months?

A: Not that I know of.

Q: Has inflammable gas been found there within 12 months? A: Yes.

Q: are any naked lights used in No.6 mine

A: One naked was used on the level.

Q: Was that on the return air-way? A: No, sir. Q: Where abouts was it used?

A: IT was used from the outside of the level to No.6 stall. From the entrance of the level to No.6 stall.

Q: That is not on the return air-way at all?

A: No sir.

Q: Nor is it contiguous to it? Is it in the vicinity of it?

A: IT is quite a way off the return airway.

Q: You know that there is a rule where coal is worked with safety lamps, no other light shall be used in the same ventilating district. Now was this ventilating light used in the same ventilating district where the safety lamps were required to be used?

A: It was in the same district, but with lots of fresh air in the level; lots of it.

Q: It was in the same district?

A: IT was in the same district.

Q: Was it used between where the safety lamps are used and the return airway?

A: NO, on the lower side of the safety lamps.

Q: Were you through the second south level that day?

A: Between 10 and 11 O’clock sometime, but I couldn’t tell the exact time.

Q: Did you detect gas?

A; I got a little gas in the level and I gave instructions to Harry King to take a little corner off that was keeping the air away from this little cavity in the roof, and I under-stand, as you will find later on, that that corner was taken off and the gas went away. There was a little gas in No.7 in the hollow of that cave.

Q: Did you make any test? A: Yes sir. Q: What did you do? A: I put up my safety lamp.

Q: How high did you raise your safety lamp? A: Within six inches of the roof.

Q: Was there enough to cause you alarm?

A: Not to amount to much, nothing to cause any alarm. In fact I have no hesitation in saying that I could have gone in there with a naked light on my head, and walked from one to the other the same day.

Q: How far did you go into the mine that day?

A: I went in after I met Mr. Matthews coming, and got the curtains up, and as soon as we got the curtains put up we had no difficulty in getting around the places.